作者 Droitcour, Amy Diane
書名 Non-contact measurement of heart and respiration rates with a single-chip microwave Doppler radar
國際標準書號 9780542706615
book jacket
說明 427 p
附註 Source: Dissertation Abstracts International, Volume: 67-05, Section: B, page: 2736
Adviser: Gregory T. A. Kovacs
Thesis (Ph.D.)--Stanford University, 2006
Microwave Doppler radar can be used for non-contact, through-clothing measurement of chest wall motion, from which heart and respiration signatures and rates can be derived in real-time. A heart and respiration rate monitor has been developed based on this principle and the radio electronics have been integrated on a single CMOS chip, making inexpensive mass-production and miniaturization of the system possible
This dissertation thoroughly explores the design requirements and trade-offs for this system, analyzing the transceiver architecture, circuit specifications, and the effects of phase noise on the system. In a direct-conversion receiver, the phase relationship between the received signal and the local oscillator has a significant effect on the demodulation sensitivity, and the null points can be avoided with a quadrature receiver. The range-correlation effect on residual phase noise is a critical factor when detecting small phase fluctuations with a high-phase-noise on-chip oscillator. Phase noise reduction due to range correlation has been experimentally evaluated, and the measured phase noise was within 5 dB of predicted values on average
Data is presented from the method comparison study in which heart and respiration rates measured with the 0.25-mum CMOS quadrature Doppler radar system were compared with those measured with standard techniques on 22 human subjects. The data from the method comparison study is used to confirm theoretical estimates of the SNR, to evaluate techniques for combining the quadrature output signals and to evaluate techniques for determining the heart rate from the heart signature
The current version of the single-chip Doppler radar cardio-respiratory rate detection system can successfully measure heart rate up to one meter and respiration rates up to two meters in most subjects that have been instructed to sit still, and it could be used to monitor sleeping or unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. A CMOS single-chip version of this technology offers a potentially inexpensive implementation that could extend applications to consumer home-monitoring products, and could enable the use of multiple transceivers to solve some system-level problems
School code: 0212
DDC
Host Item Dissertation Abstracts International 67-05B
主題 Engineering, Biomedical
Engineering, Electronics and Electrical
0541
0544
Alt Author Stanford University